C7135 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C7135: Toner supply motor/Y failure |
Rank | C |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | • Toner supply motor/Y (M9) • Expansion control board (EXCB) |
Procedure
- Check the connector between M9-EXCB CN11EX for proper connection and correct as necessary.
- Check the connector of M9 for proper drive coupling and correct as necessary.
- M9 conduction check.
- Control signal: EXCB CN11EX-9 to 12
- Location of electrical component: 4-P
- Replace M9. (Part# A7PUM10700)
- Replace EXCB. (Part# AA2JH00500)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.13.9 (Link to the Field Service Manual)