How Can We Help?

C7212 (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC7212: Tray 3 paper feed clutch failure
RankC
Trouble detection conditionAfter starting the clutch, an error is detected for the malfunction detection signal.
Trouble isolationTray 3
Relevant electrical parts– Tray 3 paper feed clutch (CL5)
– Paper feed/transport drive board (PFTDB)

Procedure

  1. Check the connector between CL5-relay CN985-relay CN118-relay CN113A-PFTDB CN16 for proper connection and correct as necessary.
  2. Check the connector of CL5 for proper drive coupling and correct as necessary.
  3. CL5 conduction check.
    • Control signal: PFTDB CN16-5 (ON)
    • Location of electrical component: 5-X
  4. Replace CL5.
  5. Replace PFTDB.

(Link to the Field Service Manual)

Table of Contents