Trouble typeC7252: IDC sensor shutter solenoid failure
RankC
Trouble detection conditionAfter starting the solenoid, an error is detected for the malfunction detection signal.
Trouble isolation
Relevant electrical parts– IDC sensor shutter solenoid (SD2)
– Base board (BASEB)

Procedure

  1. Check the connector between SD2-relay CN551-relay CN228-relay CN603-BASEB CN12E for proper connection and correct as necessary.
  2. Check the connector of SD2 for proper drive coupling and correct as necessary.
  3. SD2 conduction check.
    • Control signal: BASEB CN12E-1 (ON)
    • Location of electrical component: 13-K
  4. Replace SD2.
  5. Replace BASEB.