C7305 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7305: Paper cooling fan/in failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – Paper cooling fan/in (FM12) – Base board (BASEB) |
Procedure
- Check the connector between FM12-relay CN325-BASEB CN27E for proper connection and correct as necessary.
- Check the connector of FM12 for proper drive coupling and correct as necessary.
- FM12 conduction check.
- Control signal: BASEB CN27E-4 (REM), BASEB CN27E-6 (LOCK)
- Location of electrical component: 13-C
- Replace FM12.
- Replace BASEB.