Contents
Trouble type | C7311: Machine cooling fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | Machine cooling fan (FM1)Base board (BASEB) |
Procedure
- Check the connector between FM1-relay CN23-BASEB CN19E for proper connection and correct as necessary.
- Check the connector of FM1 for proper drive coupling and correct as necessary.
- FM1 conduction check
- Control signal: BASEB CN19E-4 (REM), BASEB CN19E-6 (LOCK)
- Location of electrical component: 10-C
- Replace FM1.
- Replace BASEB.
(Link to the Field Service Manual)