Trouble type | C7312: Toner suction fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Toner suction fan (FM2) -Base board (BASEB) |
Procedure
- Check the connector between FM2-relay CN10-BASEB CN18E for proper connection and correct as necessary.
- Check the connector of FM2 for proper drive coupling and correct as necessary.
- FM2 conduction check
- Control signal: BASEB CN18E-14 (REM), BASEB CN18E-16 (LOCK)
- Location of electrical component: 3-C
- Replace FM2. (Part# A93EM10600)
- Replace BASEB.
4750i (Part# ACT9H02013)
4050i (Part# ACT9H02002)