C7312 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7312: Toner suction fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – Toner suction fan (FM7) – Base board (BASEB) |
Procedure
- Check the connector between FM7-relay CN326-BASEB CN24E for proper connection and correct as necessary.
- Check the connector of FM7 for proper drive coupling and correct as necessary.
- FM7 conduction check.
- Control signal: BASEB CN24E-4 (REM), BASEB CN24E-6 (LOCK)
- Location of electrical component: 1-K
- Replace FM7.
- Replace BASEB.