C7319 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7319: Tacking fan/Rr failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Tacking fan/Rr (FM24) -Expansion control board (EXCB) |
Procedure
- Check the connector between FM24-relay CN404-relay CN403-relay CN401-EXCB CN8EX for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM24 conduction check.
- Control signal: EXCB CN8EX-11 (REM), EXCB CN8EX-13 (LOCK)
- Location of electrical component: 21-X
- Replace FM24. (Part# A93EM10000)
- Replace EXCB. (Part# AA7NH00500)