C7319 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C7319: Tacking fan/Rr failure | 
| Rank | C | 
| Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. | 
| Trouble isolation | – | 
| Relevant electrical parts | -Tacking fan/Rr (FM24) -Expansion control board (EXCB)  | 
Procedure
- Check the connector between FM24-relay CN404-relay CN403-relay CN401-EXCB CN8EX for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - FM24 conduction check.
- Control signal: EXCB CN8EX-11 (REM), EXCB CN8EX-13 (LOCK)
 - Location of electrical component: 21-X
 
 - Replace FM24. (Part# A93EM10000)
 - Replace EXCB. (Part# AA7NH00500)
 