C7322 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7322: Paper cooling fan/out failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – Paper cooling fan/out (FM13) – Base board (BASEB) |
Procedure
- Check the connector between FM13-relay CN323-BASEB CN27E for proper connection and correct as necessary.
- Check the connector of FM13 for proper drive coupling and correct as necessary.
- FM13 conduction check.
- Control signal: BASEB CN27E-10 (REM), BASEB CN27E-12 (LOCK)
- Location of electrical component: 14-C
- Replace FM13.
- Replace BASEB.