How Can We Help?

C7320 (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC7320: IU cooling fan/in failure
RankC
Trouble detection conditionAfter starting the fan, an error is detected for the malfunction detection signal.
Trouble isolation
Relevant electrical parts– IU cooling fan/in (FM16)
– Base board (BASEB)

Procedure

  1. Check the connector between FM16-relay CN700-BASEB CN18E for proper connection and correct as necessary.
  2. Check the connector of FM16 for proper drive coupling and correct as necessary.
  3. FM16 conduction check.
    • Control signal: BASEB CN18E-7 (REM), BASEB CN18E-9 (LOCK)
    • Location of electrical component: 14-K
  4. Replace FM16.
  5. Replace BASEB.

(Link to the Field Service Manual)

Table of Contents