C7316 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7316: Fusing edge cooling fan/3 failure, Fusing edge cooling fan/4 failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – Fusing edge cooling fan/3 (FM30) – Fusing edge cooling fan/4 (FM31) – Paper feed/transport drive board (PFTDB) |
Procedure
- Check the connector between FM30-relay CN833-relay CN166B-PFTDB CN31 for proper connection and correct as necessary.
- Check the connector between FM31-relay CN834-relay CN166B-PFTDB CN31 for proper connection and correct as necessary.
- Check the connector of FM30 for proper drive coupling and correct as necessary.
- Check the connector of FM31 for proper drive coupling and correct as necessary.
- FM30 conduction check.
- Control signal: PFTDB CN31-7 (REM), PFTDB CN31-8 (LOCK)
- Location of electrical component: 5-P
- Replace FM30.
- FM31 conduction check.
- Control signal: PFTDB CN31-10 (REM), PFTDB CN31-11 (LOCK)
- Location of electrical component: 5-P
- Replace FM31.
- Replace PFTDB.