C7502 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7502: Tray 1 upper limit sensor failure |
Rank | C |
Trouble detection condition | The tray 1 upper limit sensor (PS6) does not change even after the lapse of a predetermined period of time after tray 1 is opened and closed, after C0202 (Tray 1 feeder up/down abnormality) is detected. |
Trouble isolation | Tray 1 |
Relevant electrical parts | – Tray 1 upper limit sensor (PS6) – Paper feed/transport drive board (PFTDB) |
Procedure
- Check the connector between PS6-relay CN145B-PFTDB CN14 for proper connection and correct as necessary.
- Replace PS6.