C7501 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7501: Tray 2 upper limit sensor failure |
Rank | C |
Trouble detection condition | The tray 2 upper limit sensor (PS14) does not change even after the lapse of a predetermined period of time after tray 2 is opened and closed, after C0204 (Tray 2 feeder up/down abnormality) is detected. |
Trouble isolation | Tray 2 |
Relevant electrical parts | – Tray 2 upper limit sensor (PS14) – Paper feed/transport drive board (PFTDB) |
Procedure
- Check the connector between PS14-relay CN155B-PFTDB CN12 for proper connection and correct as necessary.
- Replace PS14.
- Replace PFTDB.