C7329 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7329: Reverse paper cooling fan/1 failure, Reverse paper cooling fan/2 failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – Reverse paper cooling fan/1 (FM4) – Reverse paper cooling fan/2 (FM5) – Paper feed/transport drive board (PFTDB) |
Procedure
- Check the connector between FM4-relay CN699-relay CN280-relay CN271A-PFTDB CN27 for proper connection and correct as necessary.
- Check the connector between FM5-relay CN700-relay CN280-relay CN271A-PFTDB CN27 for proper connection and correct as necessary.
- Check the connector of FM4 for proper drive coupling and correct as necessary.
- Check the connector of FM5 for proper drive coupling and correct as necessary.
- FM4 conduction check.
- Control signal: PFTDB CN27-1 (REM), PFTDB CN27-3 (LOCK)
- Location of electrical component: 7-P
- FM5 conduction check.
- Control signal: PFTDB CN27-5 (REM), PFTDB CN27-7 (LOCK)
- Location of electrical component: 7-P
- Replace FM4.
- Replace FM5.
- Replace PFTDB.