C7328 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7328: Suction fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | – Suction fan (FM1) – Paper feed/transport drive board (PFTDB) |
Procedure
- Check the connector between FM1-relay CN278-relay CN271B-PFTDB CN8 for proper connection and correct as necessary.
- Check the connector of FM1 for proper drive coupling and correct as necessary.
- FM1 conduction check.
- Control signal: PFTDB CN8-3 (REM), PFTDB CN8-5 (LOCK)
- Location of electrical component: 8-P
- Replace FM1.
- Replace PFTDB.