Trouble type | C7605: Power line A5 error |
Rank | C |
Trouble detection condition | The fuse detection unit detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | – High voltage unit/1 (HV1) – High voltage unit/2 (HV2) – High voltage unit/3 (HV3) – Base board (BASEB) |
Procedure
- BASEB F12E conduction check.
- Check the connector between HV1 CN1-BASEB CN9E for proper connection and correct as necessary.
- Check the connector between HV2 CN1-BASEB CN11E for proper connection and correct as necessary.
- Check the connector between HV3 CN1-BASEB CN9E for proper connection and correct as necessary.
- Replace HV1.
- Replace HV2.
- Replace HV3.
- Replace BASEB.