C7616 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7616: Power line A21 error |
Rank | C |
Trouble detection condition | The fuse detection unit detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | -Toner supply motor/YM (M4) -Toner supply motor/CK (M5) -Base board (BASEB) |
Procedure
- BASEB F5E conduction check
- Check the connector between M4-BASEB CN13E for proper connection and correct as necessary.
- Check the connector between M5-BASEB CN13E for proper connection and correct as necessary.
- Replace M4. (Part# A7PUM10700
- Replace M5. (Part# A93E401000)
- Replace BASEB. (Part# A93EH02007)
L.3.12.24 (Link to the Field Service Manual)