How Can We Help?

C7631 (bizhub C3320i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC7631: Supply power line 1 error
RankC
Trouble detection conditionAll of the fuse detection units of the same supply power line (24V10) detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts-DC power supply (DCPS)
-Base board (BASEB)

Procedure

  1. BASEB F1E, F2E, F3E, F4E conduction check
  2. Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
  3. Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
  4. Replace DCPS. (Part# AAJRR70600)
  5. Replace BASEB. (Part# A93EH02007)

L.3.12.25 (Link to the Field Service Manual)