How Can We Help?
C7632 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7632: Supply power line 2 error |
Rank | C |
Trouble detection condition | All of the fuse detection units of the same supply power line (24V21) detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | -DC power supply (DCPS) -Base board (BASEB) |
Procedure
- BASEB F5E, F6E, F20E conduction check
- Check the connector between DCPS CN4-BASEB CN3E for proper connection and correct as necessary.
- Check the connector between DCPS CN6-BASEB CN1E for proper connection and correct as necessary.
- Check the connector between SW2, SW5-relay CN36-DCPS CN3 for proper connection and correct as necessary.
- Replace DCPS. (Part# AAJRR70600)
- Replace BASEB. (Part# A93EH02007)
L.3.12.26 (Link to the Field Service Manual)