C7621 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7621: Power line B1 error |
Rank | C |
Trouble detection condition | The fuse detection unit detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | – ADU transport motor/1 (M31) – ADU transport motor/2 (M32) – Paper feed/transport drive board (PFTDB) |
Procedure
- PFTDB F25 conduction check.
- Check the connector between M31-relay CN199-relay CN166A-PFTDB CN28 for proper connection and correct as necessary.
- Check the connector between M32-relay CN199-relay CN166A-PFTDB CN28 for proper connection and correct as necessary.
- M31 load check
- Check code: 85
- Multi code: 1, 2, 3, 4
- Control signal: PFTDB CN28-14 to 17
- Location of electrical component: 4-P
- Replace M31.
- M32 load check
- Check code: 85
- Multi code: 5, 6, 7, 8
- Control signal: PFTDB CN28-10 to 13
- Location of electrical component: 3-P
- Replace M32.
- Replace PFTDB.