C7622 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7622: Power line B2 error |
Rank | C |
Trouble detection condition | The fuse detection unit detected an error for a predetermined time. |
Trouble isolation | – |
Relevant electrical parts | – Bypass paper feed motor (M27) – Paper feed motor (M22) – Paper feed/transport drive board (PFTDB) |
Procedure
- PFTDB F26 conduction check.
- Check the connector between M27-relay CN195B-PFTDB CN9 for proper connection and correct as necessary.
- Check the connector between M22-PFTDB CN10 for proper connection and correct as necessary.
- M27 load check
- Check code: 28
- Multi code: 1, 2, 3, 4
- Control signal: PFTDB CN9-3 to 6
- Location of electrical component: 17-P
- Replace M27.
- M22 load check
- Check code: 28
- Multi code: 5, 6, 7, 8
- Control signal: PFTDB CN10-1 to 4
- Location of electrical component: 18-P
- Replace M22.
- Replace PFTDB.