C762B (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC762B: Power line B11 error
RankC
Trouble detection conditionThe fuse detection unit detected an error for a predetermined time.
Trouble isolation
Relevant electrical parts– LU drive board (LUDB)
– Paper feed/transport drive board (PFTDB)

Procedure

  1. PFTDB F24 conduction check.
  2. Check the connector between LUDB CN1-relay CN425-PFTDB CN20 for proper connection and correct as necessary.
  3. Replace LUDB. (LU-205/LU-303)
  4. Replace PFTDB.