How Can We Help?

C8101 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC8101: Before reading pressure welding alienation mechanism (When DF-632 or DF-714 is installed)
RankB
Trouble detection condition<When DF-632 is installed>
-During a pressure motion being performed, the reading roll position sensor (PS11) output does not change from H to L.

-During a retraction motion being performed, the reading roll position sensor (PS11) output does not change from L to H.
<When DF-714 is installed>
-During a pressure motion being performed, the reading roll position sensor (PS4) output does not change from H to L.

-During a retraction motion being performed, the reading roll position sensor (PS4) output does not change from L to H.
Trouble isolationDF
Relevant electrical parts<When DF-632 is installed>
-Reading roll release motor (M5)
-Reading roll position sensor (PS11)
-DF control board (DFCB)
<When DF-714 is installed>
-Reading roll release motor (M4)
-Reading roll position sensor (PS4)
-DF control board (DFCB)

Procedure

When DF-632 is installed

  1. Check the connector between M5-DFCB J18 for proper connection and correct as necessary.
  2. Check the connector of M5 for proper drive coupling and correct as necessary.
  3. Check the connector between PS11-DFCB J18 for proper connection and correct as necessary.
  4. PS11 I/O check, sensor check
    • Control signal: DFCB J18-3 (ON)
    • Location of electrical component: DF-632 1-G
  5. M5 load check
    • Check code: 60
    • Multi code: 81, 82
    • Control signal: DFCB J18-4 to 5
    • Location of electrical component: DF-632 2-G
  6. Replace M5. (Part# A3CFPP6J00)
  7. DFCB F8 conduction check
  8. Replace DFCB. (Part# AAYHPP0200)

When DF-714 is installed

  1. Check the connector between M4-DFCB J18 for proper connection and correct as necessary.
  2. Check the connector of M4 for proper drive coupling and correct as necessary.
  3. Check the connector between PS4-DFCB J18 for proper connection and correct as necessary.
  4. PS4 I/O check, sensor check
    • Control signal: DFCB J18-3 (ON)
    • Location of electrical component: DF-714 1-G
  5. M4 load check
    • Check code: 60
    • Multi code: 81, 82
    • Control signal: DFCB J18-4 to 5
    • Location of electrical component: DF-714 1-G
  6. Replace M4. (Part# A3CEPP5700)
  7. DFCB F8 conduction check
  8. Replace DFCB.(Part# AAYHPP0200)

(Link to the Field Service Manual)

Table of Contents