C8107 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C8107: Glass cleaning mechanism trouble (When DF-632 or DF-714 is installed) |
Rank | B |
Trouble detection condition | <When DF-632 is installed> The document reading glass cleaning sensor (PS12) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M4) is turned ON. |
<When DF-714 is installed> The document reading glass cleaning sensor (PS13) is not turned ON after the set period of time has elapsed after the document reading glass cleaning motor (M6) is turned ON. | |
Trouble isolation | DF |
Relevant electrical parts | <When DF-632 is installed> -Glass cleaning motor (M4) -Document reading glass cleaning sensor (PS12) -DF control board (DFCB) |
<When DF-714 is installed> -Document reading glass cleaning motor (M6) -Document reading glass cleaning sensor (PS13) -DF control board (DFCB) |
Procedure
When DF-632 is installed
- Check the connector between M4-DFCB J8 for proper connection and correct as necessary.
- Check the connector of M4 for proper drive coupling and correct as necessary.
- Check the connector between PS12-DFCB J15 for proper connection and correct as necessary.
- PS12 I/O check, sensor check
- Control signal: DFCB J15-5 (ON)
- Location of electrical component: DF-632 3-G
- M4 load check
- Check code: 60
- Multi code: 65, 66, 67
- Control signal: DFCB J8-1 to 4
- Location of electrical component: DF-632 1 to 2-B
- Replace M4. (Part# A3CFPP5R00)
- Replace DFCB. (Part# AAYHPP0200)
When DF-714 is installed
- Check the connector between M6-DFCB J8 for proper connection and correct as necessary.
- Check the connector of M6 for proper drive coupling and correct as necessary.
- Check the connector between PS13-DFCB J15 for proper connection and correct as necessary.
- PS13 I/O check, sensor check
- Control signal: DFCB J15-5 (ON)
- Location of electrical component: DF-714 3-G
- M6 load check
- Check code: 60
- Multi code: 65, 66, 67
- Control signal: DFCB J8-1 to 4
- Location of electrical component: DF-714 1-B
- Replace M6. (Part# A3CFPP5R00)
- Replace DFCB. (Part# AAMNPP4901)