C8302 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C8302: Cooling fan trouble (When DF-714 is installed) |
Rank | B |
Trouble detection condition | The lock signal continues to detect L during a given time while the DF cooling fan motor (FM1) is spinning.The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is during halts. |
Trouble isolation | DF |
Relevant electrical parts | -DF cooling fan motor (FM1) -DF control board (DFCB) |
Procedure
- Check the connector between FM1-DFCB J16 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM1 load check
- Check code: 60
- Multi code: 113
- Control signal: DFCB J16-3 (ON)
- Location of electrical component: DF-714 7-G
- Replace FM1. (Part# A143PP0200)
- DFCB F6 conduction check
- Replace DFCB. (Part# AAMNPP4901)