How Can We Help?

C8101 (bizhub 754e/654e)

You are here:

Contents

Trouble type Before reading pressure/retraction alienation mechanism
Trouble code C8101
Rank B
Detection timing • During a pressure motion being performed, the read roller home sensor (PS8) output does not change from H to L.
• During a retraction motion being performed, the read roller home sensor (PS8) output does not change from L to H.
Trouble isolation
Relevant electrical parts • Reading roller pressure/retraction motor (M6)
• Read roller home sensor (PS8)
• DF control board (DFCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between M6-DFCB CN4 for proper connection, and correct as necessary.
2 Check the connector of M6 for proper drive coupling, and correct as necessary.
3 Check the connector between PS8-DFCB CN4 for proper connection, and correct as necessary.
4 PS8 I/O check, sensor check DFCB CN4-18 (ON) DF-702 10-C
5 M6 operation check DFCB CN4-20 (ON) DF-702 10-C
6 Replace M6M6 (Part# A2X0M12001)
7 DFCB ICP9 conduction check
8 Replace DFCBDFCB (Part# A3CKH00102)

Document Information ID D0001104815 Revise ID R000004

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.12.1 (Link to the Field Service Manual)

Table of Contents