C8103 (bizhub 754e/654e)
Contents
Trouble type | Lift up mechanism trouble (Upward movement) |
Trouble code | C8103 |
Rank | B |
Detection timing | The lift up upper sensor (PS2) is not unblocked after a lapse of a given time after the lift-up motor (M5) moves up (is turned forward). |
Trouble isolation | – |
Relevant electrical parts | • Lift-up motor (M5) • Lift-up upper sensor (PS2) • DF control board (DFCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M5 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connectors between PS2-relay CN110-DFCB CN5 for proper connection, and correct as necessary. | – | – |
4 | PS2 I/O check, sensor check | DFCB CN5-3 (ON) | DF-702 10-C |
5 | M5 operation check | DFCB CN11-4 to 7 | DF-702 13-C |
6 | Replace M5 (Part# A108R70400) | – | – |
7 | DFCB ICP13 conduction check | – | – |
8 | Replace DFCB (Part# A3CKH00102) | – | – |
- Link to the wiring diagram (N.2.1 Reverse automatic document feeder DF-702)
- Link to the layout drawings for related parts by each trouble code (S.103. C8103)
Document Information ID D0001104816 Revise ID R000003
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.12.2 (Link to the Field Service Manual)