Trouble type Lift up mechanism failure (Downward movement)
Trouble code C8106
Rank B
Detection timing The lift up lower sensor (PS3) is not blocked after a lapse of a given time after the lift-up motor (M5) goes down (is turned backward).
Trouble isolation
Relevant electrical parts• Lift-up motor (M5)
• Lift-up lower sensor (PS3)
• DF control board (DFCB)

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M5-DFCB CN11 for proper connection, and correct as necessary.
2Check the connector of M5 for proper drive coupling, and correct as necessary.
3Check the connector between PS3-DFCB CN12 for proper connection, and correct as necessary.
4PS3 I/O check, sensor checkDFCB CN12-12 (ON)DF-702 12-C
5M5 operation checkDFCB CN11-4 to 7DF-702 13-C
6Replace M5 (Part# A108R70400)
7DFCB ICP13 conduction check
8Replace DFCB (Part# A3CKH00102)

Document Information ID D0001104817 Revise ID R000003