C9401 (bizhub 558/458/368/308)
Contents
Trouble type | C9401: Exposure LED lighting failure |
Rank | B |
Trouble detection condition | The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. |
Trouble isolation | Scanner |
Relevant electrical parts | • LED exposure unit • Flat cable (LED exposure unit) • CCD board (CCDB) • Scanner drive board (SCDB) • MFP board (MFPB) |
Procedure
- Correct the harness connection between SCDB CN3-LU201 if faulty.
- Check the connector between SCDB CN2-MFPB CN12E for proper connection and correct as necessary. (bizhub 368/308)
- Check the connector between SCDB CN2-MFPB CN6E for proper connection and correct as necessary. (bizhub 558/458)
- Check the connector between CCDB CN3-MFPB CN1 for proper connection and correct as necessary. (bizhub 368/308)
- Check the connector between CCDB PJ3-MFPB CN9 for proper connection and correct as necessary. (bizhub 558/458)
- Replace the LED exposure unit. (bizhub 368/308 / bizhub 558/458) (Part# A7PUR71000)
- Replace CCDB. (bizhub 368/308 / bizhub 558/458) (Part# A7PUR70100)
- Replace SCDB. (bizhub 368/308 / bizhub 558/458) (Part# A7PUH01A01)
- Replace MFPB. (bizhub 368/308 / bizhub 558/458) (558 Part# A9HGH02102 / 458 Part# A9HHH02102 / 368/308 Part# A9HJH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.22.1 (Link to the Field Service Manual)