C9401 (bizhub C360i/C300i/C250i)
Contents
Trouble type | C9401: Exposure LED lighting failure |
Rank | B |
Trouble detection condition | The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment. |
Trouble isolation | Scanner |
Relevant electrical parts | • LED exposure unitFlat cable (LED exposure unit) • CCD unitScanner drive board (SCDB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Correct the harness connection between SCDB CN3-LU201 if faulty.
- Check the connector between SCDB CN2-BASEB CN6E for proper connection and correct as necessary.
- Check the connector between CCDB CN2-BASEB CN6 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the LED exposure unit. (Part# AA2JR71400)
- Replace the CCD unit. (Part# AA2JR70100)
- Replace SCDB. (Part# AA2JH01A00)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.15.1 (Link to the Field Service Manual)