How Can We Help?

C9402 – (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeExposure LED lighting abnormally
Trouble codeC9402
RankA
Detection timingThe average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Trouble isolationScanner
Relevant electrical parts• LED exposure unit (LU201)
• Flat cable (LED exposure unit)
• CCD board (CCDB)
• Scanner drive board (SCDB)
• Printer control board (PRCB)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connection between SCDB-LU201, and correct if necessary.
2Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary.
3Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary.
4Replace the LED exposure unit (Part# A61FM31100)
5Replace CCDB (Part# A61FR72100)
6SCDB F1 conduction check
7Replace SCDB (Part# A5C1H01A11)
8Replace PRCB (Part# A61FH00101)
9Replace MFPB (Part# A61FH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.13.1 (Link to the Field Service Manual)

Table of Contents