C9403 (bizhub 554e/454e)

You are here:

(1)Contents

Trouble typeCIS LED lighting failure
Trouble codeC9403
RankA
Detection timingAt the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value.
Trouble isolationScanner
Relevant electrical parts• CIS module (CIS)
• CIS power supply (CISPU)
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection between CIS and DSIPB if faulty.
2Correct the harness connection between CIS and CISPU if faulty.
3Replace CIS (Part# A3CEM70000)
4CISPU F1, F2 conduction check
5Replace CISPU (Part# A3CEPP4Y00)
6Replace DSIPB (Part# A5C1H02A01)
7Replace MFPB (Part# A61FH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.