C9404 (bizhub 554e/454e)
(1)Contents
Trouble type | CIS LED lighting abnormally |
Trouble code | C9404 |
Rank | A |
Detection timing | After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value. |
Trouble isolation | Scanner |
Relevant electrical parts | • CIS module (CIS) • CIS power supply (CISPU) • Dual scan image processing board (DSIPB) • MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Correct the harness connection between CIS and DSIPB if faulty. | – | – |
2 | Correct the harness connection between CIS and CISPU if faulty. | – | – |
3 | Replace CIS (Part# A3CEM70000) | – | – |
4 | CISPU F1, F2 conduction check | – | – |
5 | Replace CISPU (Part# A3CEPP4Y00) | – | – |
6 | Replace DSIPB (Part# A5C1H02A01) | – | – |
7 | Replace MFPB (Part# A61FH02005) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.103. C6754, C6755, C9403, C9404)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.