CA051 (bizhub 364e/284e/224e)
Contents
Trouble type | Standard controller configuration failure |
Trouble code | CA051 |
Rank | C |
Detection timing | The controller of the MFP board (MFPB) is faulty. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check to see if [Service Mode] -> [System 2] -> [Image Controller Setting] has been set to Controller 0. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more. | – | – |
2 | Check the connectors of the MFPB for proper connection and correct as necessary. | – | – |
3 | Replace MFPBMFPB (Part# A61FH02005) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.62. C5372, C6901, C6902, C6903, CA051, CA052, CA053, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD261, CD262, CD271, CD401 – CD413, CE001, CE003 – CE305, CEEE1)
Document Information ID D0001127944 Revise ID R000003
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.14.1 (Link to the Field Service Manual)