How Can We Help?

CA051 (bizhub C650i/C550i/C450i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeCA051: Standard controller configuration failure
RankC
Trouble detection conditionThe controller of the CPU board (CPUB) is faulty.
Trouble isolation
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check to see if the following setting has been correctly made: [Service Mode] -> [System 2] -> [Image Controller Setting].
  2. If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more.
  3. Check the connectors on BASEB for proper connection and correct as necessary.
  4. Replace CPUB. (C650i Part# AA7NH02P03 / C550i Part# AA7PH02P01 / C450i Part# AA7RH02P02)
  5. Replace BASEB. (Part# AA7NH02102)

L.3.17.1 (Link to the Field Service Manual)