How Can We Help?

CC152 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeROM contents error upon startup (scanner)
Trouble codeCC152
RankC
Detection timingA fault is detected in a sequence of ROM contents check of the MFPB during starting.
Trouble isolation
Relevant electrical parts

  (2)Procedure

StepActionControl signalLocation of electrical components
1Check the ROM version.
2Rewrite the firmware.
3Replace the appropriate board. MSC: MFP board (MFPB) IR: MFP board (MFPB)MFPB (Part# A61FH02005)

Document Information ID D0001127951 Revise ID R000002

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.15.2 (Link to the Field Service Manual)