How Can We Help?

CC155 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble type Finisher ROM error
Trouble code CC155
Rank C
Detection timing Data of flash ROM of the finishing options is determined to be faulty when the main power swicth is turned ON.
Trouble isolation
Relevant electrical parts <When FS-533 or FS-534 is installed> FS control board (FSCB)
<When JS-506 is installed> JS control board (JSCB)

  (2)Procedure When FS-533 or FS-534 is installed

Step Action Control signal Location of electrical components
1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
2 Rewrite the firmware.
3 Replace FSCB (FS-533/FS-534) FSCB
FS-533 (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))
FS-534 (Part# A3EPPPBE01)

When JS-506 is installed

Step Action Control signal Location of electrical components
1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
2 Rewrite the firmware.
3 Replace JSCBJSCB:
JS-506 (Part# A2YVH10102)

Document Information ID D0001127954 Revise ID R000004

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.15.3 (Link to the Field Service Manual)