How Can We Help?

CC163 (bizhub 558/458/368/308)

You are here:

Contents

Trouble typeCC163: ROM contents error (PRT)
RankC
Trouble detection conditionThe wrong model of firmware is detected in the engine during the initial connection to the engine is being checked.
Trouble isolation
Relevant electrical partsEEPROM 1 (EEPROM/1)EEPROM 2 (EEPROM/2) (bizhub 558/458 only)MFP board (MFPB)

Procedure

  1. Rewrite the firmware.
  2. Replace MFPB. (bizhub 368/308 / bizhub 558/458)(558 Part# A9HGH02102 / 458 Part# A9HHH02102 / 368/308 Part# A9HJH02102)
  3. NOTE
    • When taking the above steps, check whether MFPB is defective or not without replacing the EEPROM.
  4. 1. Turn OFF the main power switch and replace the current MFPB with a new one.
  5. 2. Update the firmware.
  6. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started.
  7. 4. When the trouble cannot be solved, reinstall the removed MFPB to the original board.
  8. If the above actions do not solve the problem, contact KM.