CC170 (bizhub C754e/C654e)
Contents
Trouble type | Dynamic link error during starting (AP0) |
Trouble code | CC170 |
Rank | C |
Detection timing | A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | If the malfunction code “C-C172” has occurred, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if “Controller 2,” “Controller 3,” or “Others” is set for [Image Controller Setting].If any of these is set, according to the kind of controller, select “Controller 0” or “Controller 1.” | – | – |
2 | Replace MFPB (Part# A2X0H02015) | – | – |
2 | When not reviving even if the above-mentioned procedure is done, contact the responsible people of KM. | – | – |
- Link to the layout drawings for related parts by each trouble code (S.99. C6901 – C6903, CA051 – CA053, CC151, CC152, CC170 – CC174, CC180 – CC186, CC191, CC211 – CC214, CC216, CD211, CD212, CD241, CD242, CD252, CD261, CD271, CD401 – CD413, CE001, CE003 – CEEE1)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.15.12 (Link to the Field Service Manual)