CD015 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CD015: HDD mirroring error master slave |
Rank | A |
Trouble detection condition | A R/W error occurs in both drives during mirroring. |
Trouble isolation | – |
Relevant electrical parts | -Hard disk (A) (HDD (A)) -Hard disk (B) (HDD (B): HD-524) |
Procedure
- Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
- Replace both hard disk (A) and hard disk (B) with new ones. (HDD (A) Part# A5C1M72H00 / HDD (B) Part# A2X0M72C00)
- Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] -> [Physical Format] and perform the function.
- Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] -> [Logical Format] and perform the function.
- If HDD Data Backup has previously been performed, select [Service Mode] -> [Enhanced Security] -> [HDD Data Backup] -> [Restore] and perform the function.
- If HDD Data Backup has not been performed previously, install voice data, etc.
L.3.18.7 (Link to the Field Service Manual)