CD252 (bizhub C364e/C284e/C224e)
Contents
Trouble type | No relay circuit boards for IC-414 mounting at IC-414 mount setting |
Trouble code | CD252 |
Rank | C |
Detection timing | EFI relay circuit boards (VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode. |
Trouble isolation | – |
Relevant electrical parts | • MFP board (MFPB) • EFI relay board (VI-506) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | If the IC-414 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if Controller 0 is set for [Image Controller Setting]. | – | – |
2 | Check the EFI relay board (VI-506) connector for proper connection and correct as necessary. | – | – |
3 | Replace EFI relay board (VI-506) (Part# A161H02801) | – | – |
4 | Replace MFPB. (Part# A5C1H0200B) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.74. C5372, C6901, C6902, C6903, CA051, CA052, CA053, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD252 – CD271, CD401 – CD413, CE001, CE003 – CE305, CEEE1)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.16.13 (Link to the Field Service Manual)