How Can We Help?

CD2D1 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeCD2D1: VLAN setting configuration error
RankB
Trouble detection conditionAt start up of the MFP, the reception condition of VLAN setting activation is not satisfied.
Trouble isolation
Relevant electrical parts-Hard disk (A) (HDD (A))
-eMMC board (eMMCB)

 Procedure

  1. Check if all VLAN setting reception conditions are satisfied.
  • A 4GB memory has been installed.
  • An HDD has been installed.
  • If the IC card reader is connected, the LDD of AU-201S has been installed.
  • The software SW12 (bit1) has been set to “PKI unsupported” (0x00). (PKI mode setting unavailable)
  • Service Mode -> [Billing Setting] -> [Management Function Choice] is set to “Not installed”.
  • Utility -> [Administrator Settings] -> [Network Settings] -> [TCP/IP Settings] is set to “ON”.
  • Utility -> [Administrator Settings] -> [Network Settings] -> [Network I/F Configuration] is set to “Wireless Only”.

L.3.18.23 (Link to the Field Service Manual)

Table of Contents