How Can We Help?

CE201 (bizhub C658/C558/C458/C368/C308/C258)

You are here:

Contents

Trouble typeCE201: Transmission operation log storage fault
RankC
Trouble detection conditionWhen the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

 Procedure

  1. Check the connectors on MFPB for proper connection and correct as necessary.
  2. Replace MFPB. (bizhub C368/C308/C258 Part# A7PUH02123 / bizhub C658/C558/C458 (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102))

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.25.4 (Link to the Field Service Manual)

Table of Contents