How Can We Help?

CE301 (bizhub C658/C558/C458/C368/C308/C258)

You are here:

Contents

Trouble typeCE301: Referring incorrect memory
RankC
Trouble detection conditionError occurred with the process inside the MFP controller.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

 Procedure

  1. Check the connectors on MFPB for proper connection and correct as necessary.
  2. Replace MFPB. (bizhub C368/C308/C258 Part# A7PUH02123 / bizhub C658/C558/C458 (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102))
  3. Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them.

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.25.5 (Link to the Field Service Manual)

Table of Contents