P-14 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Skew correction trouble |
Malfunction code | P-14 |
Malfunction detection timing | -The difference between the skew default position setting value and the cumulative amount of skew adjustment values goes over the predetermined value. -HP signals for the skew correction motor is detected the predetermined number of times during the skew correction. |
Relevant parts | -IDC sensor/Fr (IDCS/Fr) -IDC sensor/Rr (IDCS/Rr) -Drum unit/Y,M,C,K -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) -PH unit |
Procedure
- Check the drive transmission portion of the drum unit and correct as necessary.
- Clean the contact of the drum unit connector if dirty.
- Reinstall or reconnect IDCS/Fr, connectors connecting between IDCS/Fr-relay CN77-BASEB CN15E, if any of the foregoing parts is installed or connected improperly.
- Reinstall or reconnect IDCS/Rr, connectors connecting between IDCS/Rr-relay CN77-BASEB CN15E, if any of the foregoing parts is installed or connected improperly.
- Clean IDCS/Fr or IDCS/Rr if it is dirty.
- Check the connector between the PH unit-relay CN300-EXCB CN7EX for proper connection and correct as necessary.
- Check the connectors of the EXCB for proper connection and correct as necessary.
- Check the connectors on BASEB for proper connection and correct as necessary.
- Replace IDCS/Fr or IDCS/Rr. (Part# A161M50300)
- Replace the drum unit. (CMY ACV80TE / K Part# ACV80RE)
- Replace the PH unit. (Part# ACKNR70100)
- Replace EXCB. (Part# AA7NH00500)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)
NOTE
- After the PH unit is replaced, reset the skew default position for each color in [Service Mode] -> [Machine] -> [Print Head Skew Adj.] -> [Print Head Skew Adj.]
- When this alert code is displayed, according to the list, take actions to address the problem. After the problem is resolved, select [Service Mode] -> [Machine] -> [Print Head Skew Adj.] -> [Print Head Skew Reset] and perform the skew adjustment reset.