P-36 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Media sensor failure 2 (When IM-102 is installed) |
Malfunction code | P-36 |
Malfunction detection timing | -When starting the machine, or the lower front door or the right door is opened and closed, ultrasonic waves sensor error is detected. -Measure the received voltages when CLK is output and when CLK is not output, and the values are determined to be faulty. |
Relevant parts | -Envelope detection board/TX (ENVDB/TX) -Envelope detection board/RX (ENVDB/RX) -Envelope detection relay board (ENVDRB) -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Open the right door and check if there is any foreign matter such as paper.
- Check the connector between ENVDB/RX CN491-relay CN602-relay CN9-EXCB CN13EX for proper connection and correct as necessary.
- Check the connector between ENVDB/TX CN490-ENVDRB CN2 for proper connection and correct as necessary.
- Check the connector between ENVDRB CN1-relay CN253-relay CN254-EXCB CN6EX for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace EXCB. (Part# AC77H00501)
- Replace CPUB. (Part# AC77H02P02)
- Replace BASEB. (Part# AC77H02101)