C9402 (bizhub 554e/454e)
(1)Contents
Trouble type | Exposure LED lighting abnormally |
Trouble code | C9402 |
Rank | A |
Detection timing | The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job. |
Trouble isolation | Scanner |
Relevant electrical parts | • LED exposure unit (LU201) • Flat cable (LED exposure unit) • CCD board (CCDB) • Scanner drive board (SCDB) • Printer control board (PRCB) • MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connection between SCDB PJ3-LU201, and correct if necessary. | – | – |
2 | Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary. | – | – |
3 | Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary. | – | – |
4 | Replace the LED exposure unit (Part# A61FM31100) | – | – |
5 | Replace CCDB (Part# A61FR72100) | – | – |
6 | SCDB F1 conduction check | – | – |
7 | Replace SCDB (Part# A5C1H01A11) | – | – |
8 | Replace PRCB (554e Part# A61EH00101 / 454e Part# A61EH00101) | – | – |
9 | Replace MFPB (Part# A61FH02005) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.112. C9401, C9402)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.13.1 (Link to the Field Service Manual)