C0204 (bizhub 754e/654e)

You are here:

Contents

Trouble typeTray 2 feeder up/down abnormality
Trouble codeC0204
RankB
Detection timingThe tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Trouble isolationTray 2
Relevant electrical parts• Tray 2 upper limit sensor (PS14)
• Tray 2 lift-up motor (M8)
• Paper feed/transport drive board (PFTDB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M8-PFTDB CN26 for proper connection and correct as necessary.
2Check the connector of M8 for proper drive coupling and correct as necessary.
3Check the connector between PS14-relay CN155B-PFTDB CN14 for proper connection and correct as necessary.
4PS14 I/O check, sensor checkPFTDB CN14-9 (ON)4-P
5M8 operation checkPFTDB CN26-10 to 114-X
6Replace M8 (Part# A2X0M12001)
7PFTDB ICP10 conduction check
8Replace PFTDB (Part# A2X0H00202 )
9Replace PRCB (Part# A55VH00105 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.5.4