C5351 (bizhub 754e/654e)
Contents
Trouble type | DC power supply cooling fan’s failure to turn |
Trouble code | C5351 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • DC power supply cooling fan (FM9) • DC power supply (DCPU) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM9-relay CN333-PRCB CN38 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM9 operation check | PRCB CN38-1 (DRIVE) PRCB CN38-3 (LOCK) | 19-K |
4 | Replace FM9 | – | – |
5 | PRCB ICP3 conduction check | – | – |
6 | Replace DCPUDCPU (Part# 100V A2X0R70300) | – | – |
7 | Replace PRCBPRCB (Part# A55VH00105) | – | – |
- Link to the wiring diagram (N.1. bizhub 754e/654e)
- Link to the layout drawings for related parts by each trouble code (S.86. C5351)
Document Information ID D0001104797 Revise ID R000003
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.