C0206 (bizhub C658/C558/C458)
Contents
Trouble type | C0206: Tray 3 feeder up/down abnormality (When PC-115 or PC-215 is installed) |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | •Tray 3 lift-up motor (M113) •Tray 3 upper limit sensor (PS116) •PC control board (PCCB) •MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M113-PCCB CN6C for proper connection and correct as necessary.
- Check the connector of M113 for proper drive coupling and correct as necessary.
- Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
- PS116 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-115/PC-215 7-C
- M113 operation check
- Control signal: PCCB CN6C-8 to 9
- Location of electrical component: PC-115/PC-215 2-C
- Replace M113. (Part# A79JM11300)
- Replace PCCB. (Part# A2XMM11000)
- MFPB F1E conduction check
- Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)
NOTICE
Please verify all part numbers for accuracy and current version.
K.3.8.8 (Link to the Field Service Manual)